Flowserve Digital Positioner LOGIX 500 Series 338911.999.000
520MD+37-W1D200-000-0000
Flowserve Digital Positioner LOGIX 500 Series 338911.999.000
520MD+37-W1D200-000-0000
ICS IEC 61131 Workbench, USB key, multiple controllers T9083U
“ICS customers in oil and gas and other process industries will benefit from the breadth of Rockwell Automation’s
product portfolio and solutions capabilities. It also allows us to incorporate ICS’s
high availability, fault-tolerant technology into the Logix architecture extending
the reach of this technology into discrete and hybrid process applications.”
Processor module T9110
Processor base unit T9100
Analogue input module, 16 channel T9432
Digital input module, 24Vdc, 16 channel T9402
Digital input module, 24Vdc, 8 channel T9401
Digital output module, 24Vdc, 8 channel T9451
Analogue input TA, 16 channel, dual, isolated T9832
Digital input TA, 16 channel, dual, isolated T9802
Digital output TA, 24Vdc, 8 channel, dual, commoned T9852
I/O base unit T9300
Blanking cover (short) for I/O positions with TA or a Processor T9193
IEC 61131 Workbench, USB key, multiple controllers T9083U
ICS Digital output module, 24Vdc, 8 channel T9451
“ICS customers in oil and gas and other process industries will benefit from the breadth of Rockwell Automation’s
product portfolio and solutions capabilities. It also allows us to incorporate ICS’s
high availability, fault-tolerant technology into the Logix architecture extending
the reach of this technology into discrete and hybrid process applications.”
Processor module T9110
Processor base unit T9100
Analogue input module, 16 channel T9432
Digital input module, 24Vdc, 16 channel T9402
Digital input module, 24Vdc, 8 channel T9401
Digital output module, 24Vdc, 8 channel T9451
Analogue input TA, 16 channel, dual, isolated T9832
Digital input TA, 16 channel, dual, isolated T9802
Digital output TA, 24Vdc, 8 channel, dual, commoned T9852
I/O base unit T9300
Blanking cover (short) for I/O positions with TA or a Processor T9193
IEC 61131 Workbench, USB key, multiple controllers T9083U
PEPPERL + FUCHS Inductive Sensor NBN4-12GK50-E2 088549 Proximity Switch
Specification
General specifications | |
Switching function | Normally open (NO) |
Output type | PNP |
Rated operating distance | 4 mm |
Installation | non-flush |
Output polarity | DC |
Assured operating distance | 0 ... 3.24 mm |
Reduction factor rAl | 0.5 |
Reduction factor rCu | 0.4 |
Reduction factor r304 | 0.8 |
Nominal ratings | |
Operating voltage | 10 ... 30 V |
Switching frequency | 0 ... 1200 Hz |
Reverse polarity protection | reverse polarity protected |
Short-circuit protection | pulsing |
Voltage drop | ≤ 3 V |
Operating current | 0 ... 200 mA |
Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
No-load supply current | ≤ 17 mA |
Switching state indicator | LED, yellow |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Mechanical specifications | |
Connection type | cable PVC , 2 m |
Core cross-section | 0.14 mm2 |
Housing material | PBT |
Sensing face | PBT |
Housing diameter | 12 mm |
Degree of protection | IP68 / IP69K |
Multiturn absolute encoder PVM58N-011AGR0BN-1213
Model Number PVM58
Features
• Industrial standard housing Ø58 mm
• PROFIBUS interface
• 30 Bit multiturn
• Speed transfer
• Extended scaling functions
• Programmable limit switches
• Commissioning mode
• Servo or clamping flange
Manufacturer: P +F
PVM58N-011AGR0BN-1213
Multiturn absolute encoder PVM58N-011AGR0BN-1213
Industrial standard housing 58 mm
PROFIBUS interface
30 Bit multiturn
Speed transfer
Extended scaling functions
Programmable limit switches
Commissioning mode
Servo or clamping flange
Detection type : photoelectric sampling
Device type : Multiturn absolute encoder
Functional safety related parameters
MTTFd : 70 a
Mission Time (TM) : 20 a
L10h : 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load
Diagnostic Coverage (DC) : 0 %
Electrical specifications
Operating voltage : 10 ... 30 V DC
No-load supply current : max. 230 mA at 10 V DC max. 100 mA at 24 V DC
Power consumption : max. 2.5 W
Time delay before availability : < 1000 ms
Linearity : ± 2 LSB at 16 Bit ± 1 LSB at 13 Bit ± 05 LSB at 12 Bit
Output code : binary code
Code course (counting direction) : programmable cw ascending (clockwise rotation code course ascending) cw descending (clockwise rotation code course descending)
Interface type : PROFIBUS
Single turn : up to 16 Bit
Multiturn : 14 Bit
Overall resolution : up to 30 Bit
Transfer rate : 0.0096 ... 12 MBit/s
Standard conformity : PNO profile 3.062 RS-485
Connection
Terminal compartment : in removable housing cover
Standard conformity
Degree of protection : DIN EN 60529 IP65 IP66 IP67 (with shaft seal)
Climatic testing : DIN EN 60068-2-30 no moisture condensation
Emitted interference : EN 61000-6-4:2007
Noise immunity : EN 61000-6-2:2005
Shock resistance : DIN EN 60068-2-27 100 g 6 ms
Vibration resistance : DIN EN 60068-2-6 20 g 10 ... 2000 Hz
Approvals and certificates
UL approval : cULus Listed General Purpose Class 2 Power Source
Ambient conditions
Operating temperature : -40 ... 85 °C (-40 ... 185 °F)
Storage temperature : -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Material :
Combination 1 : housing: powder coated aluminum flange: aluminum shaft: stainless steel
Combination 2 (Inox) : housing: stainless steel flange: stainless steel shaft: stainless steel
Mass : approx. 600 g (combination 1) approx. 1200 g (combination 2)
Rotational speed : max. 12000 min -1
Moment of inertia : 30 gcm2
Starting torque : ≤ 3 Ncm (version without shaft seal)
Shaft load-Axial : 40 N
Shaft load-Radial : 110 N