2022년 2월 15일

[수입판매] Parker 591PX/0150/500/0011 (591PX-53315012-P00-U4A0) DC drive

 Parker 591PX/0150/500/0011 (591PX-53315012-P00-U4A0) DC drive

the parker DC drives, has the below different electric current:

1. 590P:

15A Four Quadrant Digital Drive

15A Four Quadrant Digital Drive

35A Four Quadrant Digital Drive

35A Four Quadrant Digital Drive

40A Four Quadrant Digital Drive

70A Four Quadrant Digital Drive

110A Four Quadrant Digital Drive

165A Four Quadrant Digital Drive

180A Four Quadrant Digital Drive

180A Four Quadrant Digital Drive

270A Four Quadrant Digital Drive

270A Four Quadrant Digital Drive

380A Four Quadrant Digital Drive

500A Four Quadrant Digital Drive

A Four Quadrant Digital Drive

830A Four Quadrant Digital Drive

1580A Four Quadrant Digital Drive

2200A Four Quadrant Digital Drive

2700A Four Quadrant Digital Drive

2. 591P:

15A Two Quadrant Digital Drive

35A Two Quadrant Digital Drive

40A Two Quadrant Digital Drive

70A Two Quadrant Digital Drive

110A Two Quadrant Digital Drive

165A Two Quadrant Digital Drive

180A Two Quadrant Digital Drive

180A Two Quadrant Digital Drive

270A Two Quadrant Digital Drive

270A Two Quadrant Digital Drive

380A Two Quadrant Digital Drive

500A Two Quadrant Digital Drive

A Two Quadrant Digital Drive

830A Two Quadrant Digital Drive

1580A Two Quadrant Digital Drive

2200A Two Quadrant Digital Drive

2700A Two Quadrant Digital Drive

​​

[수입판매] Lenze 9300 servo EVF9322-CVV003

 Lenze 9300 servo EVF9322-CVV003

​​

[수입판매] Lenze 9300 servo EVF9321-EV 0.37kW

 Lenze 9300 servo EVF9321-EV 0.37kW

​​

[수입판매] Lenze 9300 servo EVF9321-CVV003

 Lenze 9300 servo EVF9321-CVV003

​​

 


[수입판매] Lenze 9300 servo EVS9328-CIV003

 Lenze 9300 servo EVS9328-CIV003

​​

[수입판매] Triconex 3604E PLC Digital Output Module. TMR Type | 24 VDC Opto-Isolated | Non-commoned

 Triconex 3604E PLC Digital Output Module. TMR Type | 24 VDC Opto-Isolated | Non-commoned | 16-Point

3401 TRICONEX DO 3401 Digital Output Module

Points 16, commoned

Nominal output voltage 24 VDC

Specified operational voltage range 15 to 30 VDC

Absolute maximum output voltage 33 VDC

Absolute maximum reverse input

voltage – 0.6 VDC

Output current

Switching 4.8 A, self-limiting

3.0 A, typical

Degraded mode 0.7 A, self-limiting

1.5 A, typical

Field alarms Loss of field power, output point shorted On or Off

Loop-back thresholds 0–5 VDC = Off region

6–14 VDC = transition region

15–30 VDC = On region

Leakage to load (Off state) 1 mA

Diagnostic glitch duration 2 ms, maximum 500 s, typical

Diagnostic fault coverage

Maximum toggle rate 20 ms

Minimum toggle rate Not applicable

On state voltage drop 1.0 VDC @ 1.5 A

Loop-back scan time 1.0 ms for all 16 points

Functional earth to protective earth isolation 500 VDC, minimum

Functional earth to functional earth (logic) isolation 800 VDC, minimum

 

 

5101 Main Processor TriPak 3 Main Processor Module 3101 1 Main Processor Baseplate Kit 2101

5201 Communication Module TriPak 1 Communication Module 3201 1 Communication Module Baseplate Kit 2201

5351 Analog Input TriPak 1 Analog Input Module 3351 1 Analog Input Baseplate Kit 2351 5361 Analog Input/Digital Input TriPak 1 Analog Input/Digital Input Module 3361 1 Analog Input/Digital Input Baseplate Kit 2361

5352 Analog Input Tripak 1 Analog Input Module 3351 (RTD/TC/4-20 mA) 1 Analog Input Baseplate (RTD/TC/4-20 mA) 2352

5381 Analog Output TriPak 1 Analog Output Module 3481 1 AO Module Baseplate Kit 2481 5382 High-Current Analog Output Tripak 1 High-Current Analog Output Module 3482 1 AO Module Baseplate Kit 2481

5301 Digital Input TriPak 1 Digital Input Module 3301 1 Digital Input Baseplate Kit 2301 5302 Digital Input TriPak (high voltage) 1 Digital Input Module 3301 1 Digital Input Baseplate Kit (high voltage) 2302

5401 Digital Output TriPak 1 Digital Output Module 3401 1 Digital Output Baseplate Kit 2401 5401L Digital Output TriPak (low current) 1 Digital Output Module 3401 1 Digital Output Baseplate Kit (low current) 2401L

5402 Digital Output TriPak (high voltage) 1 Digital Output Module 3401 1 Digital Output Baseplate Kit (high voltage) 2402

5451 Solid-State Relay Output TriPak 1 Solid-State Relay Output Module 3451 1 Solid-State Relay Output Baseplate Kit 2451

5481 Pulse Input TriPak 1 Pulse Input Module 3381 1 Pulse Input Baseplate Kit 2381 2101 Main Processor Baseplate Kit 1 MP Baseplate 3000671-100 1 MP Interconnect Assembly 2920 1 Trident User Documentation (hardcopy) 8910-2 1 Accessories Kit 8401 1 Top End Cap – I/O 2910 1 Top End Cap – MP 2912 1 Bottom End Cap – I/O 2911 1 Bottom End Cap – MP 2913 2281 I/O Bus Extender Module

​​

[수입판매] TRICONEX DO 3401 Digital Output Module

 TRICONEX DO 3401 Digital Output Module

3401 TRICONEX DO 3401 Digital Output Module

Points 16, commoned

Nominal output voltage 24 VDC

Specified operational voltage range 15 to 30 VDC

Absolute maximum output voltage 33 VDC

Absolute maximum reverse input

voltage – 0.6 VDC

Output current

Switching 4.8 A, self-limiting

3.0 A, typical

Degraded mode 0.7 A, self-limiting

1.5 A, typical

Field alarms Loss of field power, output point shorted On or Off

Loop-back thresholds 0–5 VDC = Off region

6–14 VDC = transition region

15–30 VDC = On region

Leakage to load (Off state) 1 mA

Diagnostic glitch duration 2 ms, maximum 500 s, typical

Diagnostic fault coverage

Maximum toggle rate 20 ms

Minimum toggle rate Not applicable

On state voltage drop 1.0 VDC @ 1.5 A

Loop-back scan time 1.0 ms for all 16 points

Functional earth to protective earth isolation 500 VDC, minimum

Functional earth to functional earth (logic) isolation 800 VDC, minimum

​​

[수입판매] Flowserve Digital Positioner Series LOGIX 520MD

 Flowserve Digital Positioner LOGIX 500 Series 338911.999.000

520MD+37-W1D200-000-0000

​​